斯蒂克ST211A离子风咀是一种可使用压缩空气来消除静电和除尘,特别适合于人手无法接近的场合和环境.作为自动控制除静电应用.离子作用距离可达一米,需要和ST402A电源供应器一体使用(电源供应器需单独购买)
STATICST211Aionizing compressed air nozzle delivers ionizafion foneufraliae charges in very specific area such as inaccessidle frouble spof and hard fo reach area fo eliminafe dusf or cnfaminanfs and ifs re-affracfion.lf is ideally fo be insfallde fo a fixed work sfafion in order fo dissipafe sfafic charges aufomafically.Airnozzle has an effecfive area of 100mm,lf requires ST402A power Supply for operafion which musf be ordered separafely.
Specification(技术参数)
Operating Voltage(工作电压) |
5.6KV |
Ccrrent Consumption(消耗电流) |
200uA |
Operating Temperature(操作温度) |
0---50℃ |
Weight(重量) |
0.3kg |
HV cabke kebgtg(高压电缆长度) |
2Meters |
Operating air pressure(工作空气压力) |
40---70psi |
Operating air velocity(工作气流速度) |
>10m/sec |
Decay Tdst Results(测试结果)
Testing Conditions(测试条件) |
||||
Testing Voltage( 测试电压):4.6KV Testing Voltane Range(测试电压范围):5.0Kvto500V Temperature(环境温度):22℃ |
||||
Distance(距离) |
|
30mm |
90mm |
150mm |
Decay time (中和时间) |
Positve(正) |
0.1s |
0.2s |
0.9s |
Negative(负) |
0.2s |
0.2s |
0.7s |
|
Offsef volfage (残余电压) |
Positve(正) |
-28V |
-18V |
+19V |
Negative(负) |
-29V |
-17V |
+18V |
备注:
1. 风速测试在150mm处。
2. 离子测试距离在150 mm处。
3. 测试的数据会因测试时的环境空气温湿度而有所变化。
Remarks:
1. Air velocity measured at 150mm.
2. Operational ionizing distance of 150mm.
3. Test figures are subjecffo the variation in the atmospheric condifeons.