防冻结装置:当循环水温度降至6℃以下时,水泵运转,燃烧器以**小功率燃烧,水温升至20℃时停止。
Frostbite-proof Device: When the temperature
of circulating water is lower than 6℃,the water pump automatically
running.At that time,the combustor runs at the lowest power. When
the temperature reaches 20℃,the combuster stops running.
■ 水泵防卡滞功能:每待机24小事,水泵自动运作1分钟。
Lock-proof function of water pump:Every time
the machine stands by for 24 hours, the water pump will
automatically run for 1 minute.
■
水泵旁路保护装置:当供暖主回路意外关闭,水路循环停止时,旁通阀自动打开,以保护系统及水泵。
Bypass protection device of water pump: When
the main heat supply loop is closed by accident and the waterway
circulation stops, the bypass value automatically open to protect
the system and water pump.
■
主回路流量监控装置:当主回路流量太小或水循环意外停止时,自动关闭系统。
Flow monitoring device of main loop: When the
flow of main loop is too low or the circulating water stops by
accident, the system will be automatically closed.
■
极限温度保护装置:水温升高到极限温度时,关闭燃气比例阀,系统停止工作。
Limiting temperature protetion device:When the
water temperature reaches limit,the combustion proportional value
will be losed and the system stops running.
■
风压过大保护装置:当风机故障、烟道堵赛、风压过大时,燃烧自动停止。
Air pressure protection device: When the fan
doesn"t work, or the flue pipe is blocked,or the air pressure is
too high,combustion will automatically stop.
■
供暖系统水过压安全保护装置:系统水压升至3bar时,安全阀自动打开泄压。
Heat supply system water pressure protection
device:When the prssure of system water is above 3 bar,safety value
will automatically open for reducing the pressure.
■ 熄火保护功能:燃烧器以外熄火时,燃气比例阀自动关闭。
Flame-out protection device: Wher the
combustor quenches by accident,combustion proportional value will
be closed automatically.
■
水温传感器失效保护:当供暖或生活热水水温传感器故障短路,断路或阻值异常时能自动显示故障代码。
Watertemperature sensor protection device:
When the temperature sensor of water supply or living hot water
appears short circuit, or open circuit, or the resistance value is
abnormal, the sensor can show failure code.
|