Monroe ME-300离子静电测试仪,Monroe ME-268A离子静电测试仪,ME-300平板式离子静电测试仪
Monroe新产品 平板式离子静电测试仪ME-300,功能同ME-268A,测试范围为±1050 volts,完全可以满足离子风机测试使用
300 uses large, high-contrast, alpha/numeric LED displays for
easy reading at any vieweing angle, even in high ambient lighting
conditions. Individual LED’s, provide additional operation status
during testing and setup. Single-button operation of manual +decay,
-decay and balance ensures simple, easy operation. Balance tests
record ±peaks and average reading. Each test can be customized in
setup for stop trip levels and test duration. An automated set of
tests can be initiated with a single button depress.
Operation and setup can be done via a USB port and PC software in
addition to the front panel buttons. Test results can also be
retreived for automatic or manual test.
Real time analysis of ionizers can be done via the analog output.
1 Measures, displays and stores last test data, including discharge times, peak offset voltages, and average offset voltage.
2 Easiest, most reliable way to check effectiveness of all ionization-type static control systems
3 Meets Requirements of ANSI/ESD STM 3.1
4 Removable, cable-connected ion collecting plate probe permits precise positioning and remote monitoring
5 Separate time and voltage displays for discharge time test
6 Recorder output for permanent records and unattended operation
7 One range measures from 0 to ±1kV
8 SDramatically demonstrates induced charges and human body potential
9 AC and battery operation
10Perform long-term balance tests
Features:
? Measures, displays and stores last test
data, including discharge times, peak
offset voltages, and average offset
voltage.
? Easiest, most reliable way to check effectiveness of all
ionization-type static control systems
? Meets Requirements of ANSI/ESD
STM 3.1
? Removable, cable-connected ion
collecting plate probe permits precise
positioning and remote monitoring
? Separate time and voltage displays for discharge time test
? Recorder output for permanent records and unattended
operation
? One range measures from 0 to ±1kV
? Dramatically demonstrates induced charges and human body
potential
? AC and battery operation
? Perform long-term balance tests
Specifications:
Charger: ±1050 volts, selectable polarity
Fieldmeter:Range: 0 to ±1300 volts on display 0 to ±1800 volts
analog output1 volt resolution
Accuracy: ±2% of reading ±2V + zero offset
Bandwidth: 6Hz
Analog output: 1/1000 of plate voltage, ±3%
Trip Points: Start Voltage: 1000 volts fixed Stop Voltage: 10 to
990 volts in 1V steps
Charge Plate:Size: 6”x6” (15cm x 15cm)
Capacitance: 20pf, ±10%
Plate selfdischarge: Less than 100 volts within 5 minutes (< 60%
R.H.)
Timer:Range: 0.1 sec to 999.9 sec Resolution: 0.1 sec Accuracy: 0.1 sec
PowerRequirements: 100 to 220 VAC nominal line voltage; less than 5
Watts.
Battery Life: >8 hours
Dimensions: Approx 6?”W x 8?”D x 6H”