产品名称: PMS系列粉尘浓度传感器
产品型号: PMS
和DPM监控仪表配套使用
Service: Air and compatible gases, any type
particulate.
Wetted Materials: 304SS and PTFE.
Minimum Detection: 5.0 pA.
Temperature Limits: Ambient: Maximum -40 to 392°F
(-40 to 200°C) (Maximum must be calculated for each
application).
Process: See Model Chart on Ordering Page.
Pressure Limits: Standard: Full vacuum to 10 psi
(0.69 bar); Optional: 100 psi (6.89 bar).
Output Signal: pA.
Electrical Connection: Low noise coaxial.
Process Connection: See Model Chart on Ordering
Page.
Enclosure: Standard: Painted cast aluminum,
Weatherproof, NEMA 4X; Optional: Intrinsically Safe, CSA.
Weight: Varies depending on length of probe and
type of mount.
Agency Approvals: CE, CSA.
选型表
Example | PMS | A1 | 1 | T1 | P1 | L1.5 | PMS-A1P1T1P1-L1.5 Particulate Sensor, weatherproof, NEMA
4X, 1/2" NPT connection, 250°F max. temp., 10 psi max. pressure, 1.5" probe. |
Series Designator | PMS | PMS Particulate Sensor | |||||
Enclosure Rating | A1 AHZ1 |
Weatherproof,
NEMA 4X Intrinsically Safe, CSA & CE Approvals, Class I, II and III, Divisions I & II, All Groups, NEMA 4X (requires sanitary connection or flange mount). |
|||||
Process Connection | 1 2 3 4 |
1/2"
NPT 1.5" Sanitary Connection 2" 150# ANSI Flange 2" 150# ANSI Flange with Process Mating Flange and Installation Kit. |
|||||
Maximum Process Temperature |
T1 T2 T3 T4 |
250°F
(121°C) 450°F (232°C) 800°F (426°C) -requires flange mount 1200°F (649°C) - requires flange mount |
|||||
Maximum Process Pressure |
P1 P2 |
10 psi 100 psi - requires flange mount |
|||||
Insertion Length (recommended at least 1/2 duct diameter) |
L1.5 L03 L05 L10 L15 L20 L30 L36 L48 L60 L72 |
1.5" Probe |
Tel:
Tel:
Tel:
Tel: